PELLET STOVES Chapter 6
INSTALLATION AND USE MANUAL
page 46
Problems/Causes/Solutions Technical service - Rights reserved - Reproduction prohibited
PROBLEM
LED
POSSIBLE CAUSES Solutions:
The flame is weak
and goes out
The pellet hopper is emptying
Low pellet load
Unsuitable pellet
Fill the hopper
Increase the pellet load
following the instructions in
section 4.10
Remove the unsuitable
pellet from the hopper and
exchange it with one
recommended by the
manufacturer
The room fan does
not stop
The stove is cooling down
Temperature probe faulty
Wait for the structure to
cool
Replace the faulty
component
The room fan is not
working
The temperature has not reached the
minimum ignition limit
The thermal protection has triggered
due to fan overheating
Fan faulty
Wait for the structure to
cool
Check for any
impediments in the fan
rotation
Replace the faulty
component
The room fan is not
regulated by knob A
The stove has reached the room temperature
set by knob B and automatically modulates at
minimum
Control panel faulty
Increase the temperature
set using knob B
Replace the faulty
component
The stove power is
not regulated by
knob C
The stove has reached the room temperature
set by knob B and automatically modulates at
minimum
Control panel faulty
Increase the temperature
set using knob B
Replace the faulty
component
No light signals on
the power supply
switch of the stove
The power supply cable is unplugged
The switch is not lit on I
No voltage
Fuse blown.
Connect the cable to the
socket plug
Ignite the stove using
switch I
Check the system
Replace the fuses
(section.4.4)